Typical repair breakdown faults are:

Leaking hydraulic cylinders requiring the seals replacing
Low hydraulic pressure often caused by over heating
Hydrauico oil temperature should not exceed 150 degrees fahrenheit Hydraulic filters in need of cleaning or changing
Replace the air cooled heat exchangers filter

Slow pressure build up,i.e more than 2 seconds – check relief valve is working

Faulty Hydraulic pump motor the motor nipple has not been used as recommended by the

motor manufacturer

Oil leaks – Tighten or replace leaking hoses or fitting

Electrical faults such as sticking contactors, faulty solenoids